BOSCH - Analog Fire Alarm Systems

The FPA‑1000 Analog Addressable Fire Panels are a scalable solution for fire detection. Protect your small office with a single system or connect multiple panels together as your needs grow. Networking capabilities support the monitoring of up to 2,000 addressable points in one system for campuses or other large commercial environments.
Dual Ray Analog Smoke Detectors

Features
- Dual Ray Technology provides better particle size differentiation resulting in fewer false alarms
- Smoke threshold is adjustable and automatically compensated
- Rotary switch addressing
- Flexible work modes determined by the control panel
- Selectable base locking mechanism prevents malicious removal of the detector
- The FAP‑440 Dual Ray Detectors are open-area smoke detectors of which some models are enhanced with heat or heat and CO sensors.
Photoelectric Analog Smoke Detector

Features
- Addressable analog photoelectric smoke detector head that mounts on D321A or D336A Analog Detector Base
- Advanced digital communications protocol
- Digital data communications and power provided over two-wire circuit
- Easy head removal for cleaning and servicing
- Dual Polling Status and Latching Alarm LEDs on head for easy viewing
Ionizations Analog Smoke Detector

Features
- Advanced digital communications protocol
- Digital data communications and power provided over a two‑wire circuit
- Mounts on a D321A or a D336A Analog Detector Base
- Easy head removal for cleaning and servicing
- Dual Polling Status and Latching Alarm LEDs on head for easy viewing
Analog Heat Detector

Features
- Selectable Fixed Temperature threshold
- Rate-of-Rise feature can be switched on or off
- Selectable base locking mechanism prevents malicious removal of the detector
Analog Detector Base

Features
- Modular design
- Easy detector removal for cleaning and servicing
- Stable mounting of detectors
- Terminal screws for remote LED, Data In and Out provided
- Some models include isolator circuitry which prevents the entire SLC loop from being disabled when a short circuit occurs
D328A Photoelectric Analog Smoke Detector

Features
- Addressable analog photoelectric smoke detector head that mounts on D321A or D336A Analog Detector Base
- Advanced digital communications protocol
- Digital data communications and power provided over two-wire circuit
- Easy head removal for cleaning and servicing
- Dual Polling Status and Latching Alarm LEDs on head for easy viewing
D324A Ionisation Analog Smoke Detector

Features
- Advanced digital communications protocol
- Digital data communications and power provided over a two‑wire circuit
- Mounts on a D321A or a D336A Analog Detector Base
- Easy head removal for cleaning and servicing
- Dual Polling Status and Latching Alarm LEDs on head for easy viewing
D322A Analog Heat Detector

Features
- Advanced digital communications protocol
- Digital data communications and power provided over a two-wire circuit
- Mounts on D321A or D336A Analog Detector Bases
- Easy head removal for cleaning and servicing
- Dual Polling Status and Alarm Latching LEDs on head for easy viewing
Analog Sounder Base

Features
- Sound pressure level of 85 dB at 10 ft
- Can be alarmed by zone or by host
- Base learns the detector address and adds 127 to it (address range from 128‑254)
- Digital data communications via the attached detector and powered over a four‑conductor circuit
- Compatible with advanced digital communications protocol (DCP)
FAA‑325‑B6 6‑inch Analog Sensor Base

Features
- Modular design
- Robust six‑inch detector base
- Easy sensor removal for cleaning and servicing
- Stable mounting of sensors
- Terminal screws for remote LED, Data In and Out provided
FMM‑325A Series Analog Manual Stations

Features
- Compatible with advanced digital communication protocol
- Digital data communications and power provided over two-wire circuit
- EEPROM addressing in module unit
- Rugged die‑cast housing and corrosion resistant construction
- Single‑gang mounting
D327A Analog NAC Module

Features
- Compatible with advanced digital communications protocol
- Provides digital data communications and power over a two-wire circuit
- Provides Class B circuit for notification appliances
- Supervised connection point for 24 VDC input
- Two-color status LED
D328A Analog Relay Module

Features
- Advanced digital communications protocol
- Digital data communications and power provided over a two-wire circuit
- Provides one Form C relay output
- Two-color Status LED
- EEPROM addressing in module unit
D333A Analog Circuit Fault Isolator

Features
- Reduces lost devices under fault conditions
- Supports Class A, Style 7 wiring and Class B, Style 4 wiring
- LED identifies polling circuit faults
- Uses up to 127 circuit fault isolators per circuit
D326A Analog Point Contact Module

Features
- Digital data communications and power provided over a two-wire circuit
- Advanced digital communications protocol compatible
- Class B circuit for dry contact devices
- Two-color status LED: green for normal, red for alarm
- EEPROM addressing in module unit
D7035 Series Octal Relay Modules

Features
- Eight Form C programmable relay outputs
- D7035 mounts conveniently inside the FACP enclosure; no separate enclosure needed
- D7035B includes mounting skirt and enclosure for mounting outside of the FACP enclosure
- Up to two modules are supported by the FACP
FLM-325-I4-A Family Contact Monitors

Features
- Monitors Normally Open (NO) or Normally Closed (NC) contacts
- Monitored Normally Closed (NC) contacts can be configured with or without EOL resistor
- Module address programming with the D5070 Analog Device Programmer
- Bi‑colored LED provides module status
- Digital data communications and power over a two‑wire circuit
FLM‑325‑IM Contact Module

Features
- Digital data communications and power provided over a two-wire circuit
- Advanced digital communications protocol compatible
- Class B circuit for dry contact devices
- Module address programming (1-254) with the D5070 Analog Device Programmer
FLM‑325‑2I4 Dual Input Monitor

Features
- Two independent contact monitoring circuits
- Monitors Normally Open (NO) or Normally Closed (NC) contacts
- Monitored Normally Open (NO) contacts can be configured with or without EOL resistor
- Module address programming with the D5070 Analog Device Programmer between 1‑127
- Bicolored LED provides module status
FLM‑325‑2R4 Dual Relay Module

Features
- Two independently configurable Form C contacts
- Contacts are rated 1 A at 30 VDC or 0.5 A at 125 VAC
- Module address programming with the D5070 Analog Device Programmer between 1‑127
- Bi‑colored LED provides module status
- Digital data communications and power over a four‑wire circuit
FLM‑325‑CZM4 Conventional Zone Module

Features
- Provides a zone of up to 25 conventional smoke detectors (depending on detector type)
- Supervises auxiliary power supply for conventional detectors
- Compatible with Class B (Style B) or Class A (Style D)
- Module address programming with the D5070 Analog Device Programmer between 1 and 127
- Bi‑colored LED provides module status
FMR‑1000‑RA Remote Annunciator

Features
- LED status indicators
- 80‑character LCD display
- Piezo sounder
- Navigation buttons
- Acknowledge key
FMR‑1000‑RCMD Remote Command Center

Features
- LED status indicators
- 80‑character LCD display
- Piezo sounder
- Navigation buttons
- Operations keys for drill, reset, silence, and acknowledge